Custom Pressure Vacuum Relief Valve for Cement Tanker and Silo
Home » Products » Discharge Equipment » Slag Silo » Custom Pressure Vacuum Relief Valve for Cement Tanker and Silo
Custom Pressure Vacuum Relief Valve for Cement Tanker and Silo
Custom Pressure Vacuum Relief Valve for Cement Tanker and Silo Custom Pressure Vacuum Relief Valve for Cement Tanker and Silo
AA AA
AA AA
AA AA
AA AA

loading

Custom Pressure Vacuum Relief Valve for Cement Tanker and Silo

5 0 Reviews
Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
The pressure vacuum relief valve is an essential safety device installed on the top of bulk material storage silos, cement silos, fly ash bins and dust collectors. It automatically opens to release excess positive pressure when the internal pressure exceeds the calibrated set point, and opens inward to break vacuum when negative pressure threatens to collapse the silo structure. This silo pressure relief valve features a robust cast iron or carbon steel body with epoxy gray paint finish, a flanged bottom connection for bolt-on installation, and a hinged top cover with side latch mechanism for easy inspection and maintenance. The spring-loaded valve core ensures accurate and repeatable pressure relief performance. Standard flange sizes range from DN100 to DN300, with custom sizes and pressure settings available. As a professional pressure relief valve manufacturer, we supply these silo safety valves to concrete batching plants, cement terminals, steel mills, chemical plants and bulk material handling facilities worldwide. The bin vent valve protects both personnel and equipment by preventing catastrophic silo failure caused by overpressure or vacuum conditions during pneumatic conveying, filling and emptying operations. Custom pressure vacuum relief valve designs are available to match specific project requirements.
 
  • KCY

Availability:
Quantity:


Product Overview

banner_01_product_name


Product Overview
Our pressure vacuum valve series is engineered for reliable overpressure and vacuum protection in powder and bulk material storage applications. The spring loaded relief valve uses precision-calibrated springs that respond instantly to pressure changes, opening at the set pressure and reseating tightly when normal conditions return. The valve body is constructed from heavy-duty cast steel with corrosion-resistant epoxy coating, suitable for the dusty and abrasive environment of cement plants and bulk terminals. The hinged cover design allows quick access to the internal valve disc and spring for inspection and cleaning without removing the entire valve from the silo. Standard positive pressure settings range from 0.01 bar to 0.1 bar, and vacuum breaking settings from -0.005 bar to -0.05 bar, all fully customizable. Flange dimensions comply with DIN, ANSI or JIS standards upon request. This overpressure relief valve is widely used on cement silos, fly ash storage bins, dust collector hoppers, bulk cement tanker trucks and material processing silos. We also provide the vacuum breaker valve as a separate unit or combined dual-function valve. As an experienced pressure relief valve factory, we offer competitive factory pricing, fast delivery, and complete technical support including installation drawings, pressure setting certificates and after-sales service.Our pressure vacuum valve series is engineered for reliable overpressure and vacuum protection in powder and bulk material storage applications. The spring loaded relief valve uses precision-calibrated springs that respond instantly to pressure changes, opening at the set pressure and reseating tightly when normal conditions return. The valve body is constructed from heavy-duty cast steel with corrosion-resistant epoxy coating, suitable for the dusty and abrasive environment of cement plants and bulk terminals. The hinged cover design allows quick access to the internal valve disc and spring for inspection and cleaning without removing the entire valve from the silo. Standard positive pressure settings range from 0.01 bar to 0.1 bar, and vacuum breaking settings from -0.005 bar to -0.05 bar, all fully customizable. Flange dimensions comply with DIN, ANSI or JIS standards upon request. This overpressure relief valve is widely used on cement silos, fly ash storage bins, dust collector hoppers, bulk cement tanker trucks and material processing silos. We also provide the vacuum breaker valve as a separate unit or combined dual-function valve. As an experienced pressure relief valve factory, we offer competitive factory pricing, fast delivery, and complete technical support including installation drawings, pressure setting certificates and after-sales service.


Technical Specification


banner_02_technical_parameters


Product Name Pressure Vacuum Relief Valve / Silo Safety Valve
Type Spring-loaded, hinged cover, flanged connection
Application Cement silo, fly ash bin, dust collector, tanker truck
Positive Pressure Setting 0.01 - 0.1 bar (customizable)
Vacuum Breaking Setting -0.005 to -0.05 bar (customizable)
Flange Size DN100, DN150, DN200, DN250, DN300 (custom)
Flange Standard DIN, ANSI, JIS (upon request)
Body Material Cast iron / Carbon steel / Stainless 304/316L
Paint Finish Gray epoxy painted (custom color available)
Cover Type Hinged flat cover with side latch
Sealing Material NBR rubber / Silicone / EPDM (optional)
Operating Temperature -20°C to +120°C (standard)
Installation Flanged bolt-on on silo roof
Maintenance Hinged cover opens for inspection
Operation Type Fully mechanical, no power required
Mounting Orientation Vertical, on top of silo
Custom Options Pressure setting, flange size, material, color
Weight Per model specification (25-150 kg)
Warranty 12 months after commissioning
Origin Qingdao, China


Product Dscription


sec_01_front_view The pressure vacuum relief valve operates on a spring-loaded principle: when internal silo pressure exceeds the calibrated spring tension, the valve disc lifts and opens, releasing excess air to the atmosphere.
sec_05_hinge_latch For vacuum protection, the valve disc lifts inward when negative pressure exceeds the vacuum breaking setting, allowing air to enter and equalize pressure before the silo wall is damaged.
sec_07_paint_texture The flanged bottom connection matches standard silo roof flange dimensions. Simply bolt the valve in place with gasket and connect - no welding or special tools required for installation.
sec_03_top_view The hinged top cover opens upward on its side hinge, providing full access to the internal valve disc and spring for inspection, cleaning or spring replacement.
main_02_silo_roof_closeup The gray epoxy paint finish resists corrosion from cement dust, fly ash and chemical powders. The coating is durable and easy to clean, maintaining the valve appearance for years of service.
main_06_dust_collector Pressure settings are factory-calibrated and sealed. The positive pressure relief point and vacuum breaking point can be specified at order time for your specific silo and conveying system requirements.


Customization


banner_04_accept_customization


custom_02_dimension_overlay We offer custom pressure vacuum relief valve design based on your specific silo dimensions, conveying system pressure, and material characteristics. Customization includes flange size and drilling pattern (DIN/ANSI/JIS), positive pressure setting (0.01-0.1 bar), vacuum breaking setting (-0.005 to -0.05 bar), body material (cast iron, carbon steel, stainless steel 304/316L), and paint color. Our engineering team reviews your silo P&ID drawings and provides a tailored valve specification within 3 working days.
custom_03_exploded_view Tailor-made silo safety valves to match your existing silo roof flange and mounting space. We can modify the overall height, flange outer diameter, and bolt circle to fit retrofitting projects. Special options include high-temperature gaskets for hot cement applications, stainless steel internals for corrosive chemicals, and explosion-proof rated construction for hazardous dust environments. Voltage and signal options are not applicable for this mechanical valve type, but position indicator switches can be added for remote monitoring.
custom_04_installation_dimension Custom bin vent valve solutions include integrating the relief valve with silo filter systems, pneumatic conveying blow tanks, and bulk tanker truck loading stations. We provide 3D mounting layout drawings, foundation load calculations, and flange interface dimension drawings for your EPC project team. Special variants include combined pressure relief and filter units, low-profile valves for height-restricted installations, and heavy-duty valves for large silos over 1000 tons capacity. Our custom relief valve service ensures perfect compatibility with your bulk material handling infrastructure.
custom_01_product_cad_split OEM and private label manufacturing available for silo equipment distributors and system integrators. We can brand the pressure vacuum relief valve with your company logo on the valve body, custom color scheme, and documentation in your local language. Custom spare parts kits, export wooden crate packaging, and CIF/DDP shipping arrangements tailored to your logistics requirements. Our factory supports MOQ from 1 unit with custom engineering review. Contact us with your specifications for a custom relief valve quotation within 48 hours. Complete package includes valve body, flange gasket, mounting bolts, and calibration certificate.


Advantage


banner_03_product_advantages



1 Dual-function design provides both positive pressure relief and vacuum breaking in one compact unit.
2 Spring-loaded mechanism ensures accurate and repeatable pressure opening and closing.
3 Flanged bottom connection allows simple bolt-on installation on standard silo roof flanges.
4 Hinged top cover enables quick inspection and cleaning without removing the valve from the silo.
5 Cast steel body with epoxy paint resists corrosion from cement dust and chemical powders.
6 Protects silos from catastrophic overpressure failure during pneumatic conveying filling.
7 Prevents silo collapse from vacuum during emptying or fan shutdown events.
8 Factory-calibrated and sealed pressure settings ensure consistent performance.
9 Multiple standard flange sizes from DN100 to DN300 match common silo configurations.
10 Custom pressure settings available to match specific conveying system requirements.
11 Weather-sealed construction suitable for outdoor silo roof installation year-round.
12 Low maintenance design - no power supply required, purely mechanical operation.
13 Automatically reseats after pressure normalization - no manual reset required.
14 Direct manufacturer supply means competitive factory price and short lead time.
15 Suitable for wide range of bulk materials: cement, fly ash, lime, grain, chemicals.
16 Compact axial design saves silo roof space compared to larger relief assemblies.
17 Heavy duty construction withstands years of dusty industrial service conditions.
18 Each valve comes with pressure test certificate for quality and safety assurance.
19 Can be retrofitted to existing silos with matching flange dimensions.
20 Stainless steel body option available for food, pharmaceutical or corrosive service.
21 Wide operating temperature range from -20°C to +120°C standard, higher options available.
22 Position indicator switch option available for remote monitoring and automation.
23 Lower cost alternative to rupture disc systems - no replacement parts needed.
24 Smooth valve disc action prevents material leakage and dust emission.
25 Available for cement tanker trucks as well as stationary silo installations.
26 Fast response to pressure spikes protects silo from sudden overpressure events.
27 Easy to identify and replace wear parts like gaskets and valve disc seals.
28 Compliant with international bulk material storage safety standards.
29 Professional installation guidance and technical support available worldwide.
30 Proven design with thousands of units installed in cement plants and bulk terminals.


FAQ


banner_05_split_template



1 What is a pressure vacuum relief valve used for? It is a safety device installed on silo tops to protect against both overpressure (positive) and vacuum (negative) conditions during pneumatic conveying, filling and emptying operations.
2 How does a silo pressure relief valve work? Spring-loaded valve disc opens when internal pressure exceeds the calibrated positive setting, releasing air. For vacuum, the disc lifts inward when negative pressure reaches the breaking point, letting air in.
3 Where should I install the relief valve on my silo? Install on the silo top center or near the air inlet point. The valve should be on the highest point of the silo roof, connected via the standard roof flange.
4 What pressure settings are available? Standard positive pressure settings range from 0.01 bar to 0.1 bar. Vacuum breaking settings range from -0.005 bar to -0.05 bar. Custom settings are available upon request.
5 What flange sizes do you offer? Standard flange sizes are DN100, DN150, DN200, DN250 and DN300. We can also customize flange dimensions and drilling patterns to match your existing silo roof flange.
6 Can the valve handle cement dust and abrasive materials? Yes, the cast steel body with epoxy paint and NBR rubber seal are designed for cement dust and abrasive powder environments. Stainless steel internals are available for highly corrosive materials.
7 Do I need a pressure relief valve on my cement silo? Yes, pneumatic filling creates positive pressure, while suction during emptying creates vacuum. Without a relief valve, the silo can bulge or collapse, creating a serious safety hazard.
8 What is the difference between pressure relief and vacuum relief? Pressure relief opens outward to release excess positive pressure during filling. Vacuum relief opens inward to let air in and prevent silo collapse during emptying or fan shutdown.
9 How do I maintain the relief valve? Open the hinged cover periodically to inspect the valve disc and spring. Check seal condition and clean any dust buildup. Re-grease hinge pin annually. No major maintenance required under normal operation.
10 Can I adjust the pressure setting after installation? The pressure setting is factory-calibrated and sealed. Field adjustment requires changing the spring, which is a factory or authorized service procedure. We recommend ordering the correct setting upfront.
11 What materials are available? Standard body is cast iron with gray epoxy paint. Options include carbon steel, stainless steel 304, and stainless steel 316L for corrosive or food-grade applications.
12 Is the valve suitable for outdoor installation? Yes, the weather-sealed hinge and epoxy-painted body are designed for outdoor silo roof installation. The valve operates reliably in all weather conditions from -20°C to +120°C.
13 How long is the delivery time? Standard flange sizes are in stock and ship within 7 days. Custom valves with special pressure settings or materials typically require 15-25 days manufacturing time.
14 Can the valve be used on a cement tanker truck? Yes, smaller flange sizes (DN100-DN150) are commonly used on bulk cement tanker trucks for pressure and vacuum protection during pneumatic loading and unloading.
15 What is the warranty? We provide a 12-month warranty after commissioning or 18 months from shipment, whichever comes first. The warranty covers manufacturing defects under normal operating conditions.
16 How does this compare to a rupture disc? A rupture disc bursts once and must be replaced. Our spring-loaded valve opens and reseats automatically, providing continuous protection with no replacement parts needed over years of service.
17 Do you provide installation drawings? Yes, we provide general arrangement drawings, flange dimension drawings and pressure setting certificates with each order. Custom drawings are available for special project requirements.
18 What happens if the valve fails? The valve is a purely mechanical device with no electronic components, making it highly reliable. In the rare event of failure, the hinged cover allows easy inspection and replacement of internal parts.
19 Can I get a sample for testing? Yes, we can supply a sample unit for your evaluation. Sample units are available from stock models. Contact us for sample pricing and lead time.
20 What industries use these valves? They are widely used in concrete batching plants, cement terminals, fly ash silos, dust collectors, chemical powder storage, grain silos and bulk material handling facilities.
21 Is there a position indicator option? Yes, we can add a proximity switch or limit switch to indicate when the valve opens, for remote monitoring and automation system integration.
22 Can the valve handle high temperature cement? Standard valves handle up to 120°C. For hot cement applications above this, we offer high-temperature gaskets and special seal materials rated up to 200°C.
23 How do I select the right flange size? Flange size depends on your silo roof opening and conveying air volume. As a general guide: small silos use DN100-DN150, medium silos use DN200, large silos use DN250-DN300.
24 What spare parts do I need? Recommended spare parts include the sealing gasket, valve disc seal, and spring. Original spare parts ensure proper pressure setting and sealing performance.
25 Is the valve suitable for food-grade applications? Yes, we offer stainless steel 304/316L body with food-grade gaskets for grain, flour and other food powder silos. These units meet sanitary design requirements.
26 Can multiple valves be installed on one silo? Yes, large or high-flow silos may require 2 or more relief valves installed at different points. Our engineering team can recommend the optimal number and placement.
27 What is the lead time for custom designs? Custom design review and quotation takes about 3-5 working days. Engineering drawings and detailed design take 10-15 working days before manufacturing begins.
28 How should I clean the valve? Wipe the exterior with a dry cloth. Open the hinged cover to brush out any accumulated dust from the valve seat. Do not use water jet on the internal spring mechanism.
29 Does the valve meet international standards? Our valves are designed and manufactured in accordance with international pressure vessel and bulk material handling safety standards. Test certificates are provided for each unit.
30 How do I get a quotation? Please send us your requirements including flange size, pressure setting, body material, quantity and destination port. We will reply with a detailed quotation within 24-48 hours.


4


10


5

6

7

Qingdao Kechengyi Environmental Protection and Electric Power Technologies Co. LTD (KCY) is a comprehensive enterprise focusing on equipment research & development...

Quick Links

Product Category

Contact Us
Tel: +86-15895221943
Add: Sanlihe Industrial Park, Jiaozhou City, Qingdao, Shandong Province
Copyright © 2024 KCY All Rights Reserved. | Sitemap | Privacy Policy