KCY
| Availability: | |
|---|---|
| Quantity: | |

| Product Overview |
| Our rotary drum dryer and cooler is engineered for heavy-duty continuous operation in the most demanding industrial environments. The cylinder shell is constructed from high-strength steel plate with external reinforcing rings and internal wear-resistant liner plates where required. The drum is supported on precisely machined riding rings that rest on hardened steel support rollers with self-aligning bearings, ensuring smooth, low-friction rotation with minimal maintenance. The girth gear is made of cast steel with precisely cut teeth, driven by a heavy-duty gearmotor through a flexible pinion coupling. All rotating components are aligned and aligned at the factory before shipment, requiring only final alignment on site. The inlet end features a bolted flanged housing with feed chute, observation port and connection for hot material input. The outlet end has a matching discharge hood with product outlet, exhaust gas or cooling water connection, and inspection access. Cooling options include: indirect water-cooled jacket (sealed, no contact with product), direct counter-flow air cooling (air drawn through the drum), or a combined system. The entire assembly is mounted on a welded structural steel skid with anchor bolt holes, ready for foundation mounting. We offer complete customization: drum diameter and length, rotation speed, drive power, material of construction (carbon steel, stainless 304/316L, or wear-resistant alloy), cooling method, inlet/outlet configuration, and instrument connections (temperature sensors, level indicators). As a turnkey rotary drum dryer factory, we provide process flow diagrams, GA drawings, foundation load data, installation supervision, commissioning and operator training. Our equipment is proven in thousands of installations across power, cement, mining, steel and chemical industries worldwide. |
Technical Specification

| Product Name | Rotary Drum Cooler / Rotary Drum Dryer |
| Type | Horizontal rotating cylinder, girth gear driven |
| Application | Fly ash, clinker, slag, limestone, chemical powder |
| Diameter Range | 0.8m - 2.5m (customizable) |
| Length Range | 6m - 20m (customizable) |
| Rotation Speed | 1 - 10 RPM (VFD adjustable) |
| Cooling Method | Indirect water jacket / Direct air cooling / Combined |
| Max Inlet Temp | 300°C - 500°C (depending on material) |
| Discharge Temp | Below 80°C (customizable) |
| Shell Material | Q235B / Q345R / Stainless 304/316L |
| Drive Type | Girth gear + pinion + gearmotor |
| Support Type | Two pairs of support rollers + thrust roller |
| Base Frame | Welded steel skid with anchor bolt holes |
| End Connections | Bolted flanged end caps with inspection hatch |
| Internal Fittings | Lifting flights (lifters), optional wear liners |
| Power Range | 5.5 kW - 75 kW (depending on size) |
| Custom Options | Size, material, cooling method, lining, instrumentation |
| Installation | Skid-mounted, bolt to foundation |
| Warranty | 12 months after commissioning |
| Origin | Qingdao, China |
Product Dscription
The rotary drum shell is fabricated from high-strength steel plate, rolled and welded to a precise cylindrical form with longitudinal and circumferential welds.
Internal lifting flights (lifters) are welded inside the drum to lift and shower the material as it rotates, maximizing heat exchange with the cooling medium.
The girth gear ring surrounds the drum circumference and meshes with a drive pinion connected to a gearmotor, providing smooth and reliable rotary motion.
Support roller assemblies carry the drum weight on hardened riding rings, with self-aligning bearings for smooth low-maintenance rotation.
The flanged end caps are bolted to the drum end rings, providing easy access to the interior for inspection, liner replacement and cleaning.
The welded steel skid base frame provides a rigid platform for all components and includes anchor bolt holes for foundation mounting. Customization

We offer complete custom rotary drum cooler design based on your material type, inlet temperature, required outlet temperature, and throughput capacity. Customization includes: drum diameter (0.8m-2.5m), length (6m-20m), rotation speed and drive power, choice of cooling method (indirect water jacket, direct air cooling, or combined), internal flight configuration, and material of construction (carbon steel Q235B, wear-resistant steel, stainless 304/316L). Our engineering team provides thermal calculation, mechanical design, GA drawings, foundation load data, and P&ID. Special options include: explosion-proof drive for combustible dust, high-temperature alloy for >400°C service, insulated cladding for heat recovery, and flanged inlet/outlet to match your existing ductwork.
Tailor-made rotary drum dryer configurations for your specific process requirements. We can design the drum as a cooler only, a dryer only, or a combined cooler-dryer unit. Multi-stage drums with internal partitions allow different temperature zones in a single shell. We customize the support arrangement: standard two-pair roller support, or special pedestal designs for heavy loads. The drive system can be girth gear with pinion (heavy duty), chain drive (low speed), or friction roller drive (clean food-grade). We offer both open-air and insulated/weather-protected designs. Our engineers review your process flow diagrams, material test data (bulk density, particle size, abrasiveness, moisture), and site constraints to deliver an optimized rotary drum solution.
OEM and turnkey project services for EPC contractors and industrial plant operators. We supply complete rotary drum packages including engineering design, fabrication in our factory, transport to site, field erection supervision, commissioning and operator training. Custom branding with your company nameplate is available for OEM clients. We can also provide: spare parts packages, wear liner kits, long-term maintenance contracts, and retrofit/upgrade solutions for existing rotary drums. Our factory supports project-based MOQ with dedicated engineering review. Contact us with your process data (material name, inlet/outlet temp, capacity t/h, available plot size) for a custom rotary drum quotation within 5 working days. Complete package includes drum body, drive unit, support frame, inlet/outlet housings, all piping, local control panel, cabling and documentation.
Custom fabrication with flexible internal and external options. Internal options: replaceable wear liners (cast stone, ceramic, or alloy steel), special flight designs (bevel, C-type, cascading), and internal partitions for multi-zone operation. External options: bolted jacket for water cooling, external insulation with aluminum cladding, access platforms and ladders, and pressure vessel certification for pressurized applications. We customize the surface finish: standard painted carbon steel, polished stainless steel for food/pharmaceutical service, or hot-dip galvanized for outdoor corrosion protection. The base frame height, inlet/outlet orientation, and drain/vent connections are all engineered to your site layout. We provide GA drawings for client approval before fabrication begins, and can accommodate third-party inspection (SGS, BV, TUV) at the factory. Advantage

| 1 | Continuous rotary operation provides uniform cooling with consistent discharge temperature. |
| 2 | Gentle material tumbling reduces abrasion and breakage of fragile materials. |
| 3 | Girth gear drive ensures positive, reliable rotation with long service life. |
| 4 | Support roller design allows thermal expansion of the drum during operation. |
| 5 | Flanged end caps enable quick internal access for inspection and maintenance. |
| 6 | Heavy welded steel skid base simplifies foundation and installation. |
| 7 | Variable speed drive optimizes cooling for different materials and capacities. |
| 8 | Indirect water jacket cooling prevents product contamination and dust emission. |
| 9 | Internal lifting flights maximize heat exchange efficiency as material showers. |
| 10 | Suitable for high-temperature feed up to 300-500°C depending on design. |
| 11 | Single unit handles both cooling and conveying between process stages. |
| 12 | Low operating cost with minimal power requirement and long wear part life. |
| 13 | Completely enclosed drum prevents dust leakage into the workplace. |
| 14 | Custom drum length and diameter for any required cooling duty. |
| 15 | Proven design with thousands of units in cement, power and mining service. |
| 16 | Stainless steel construction available for corrosive or food-grade materials. |
| 17 | Factory pre-aligned components reduce on-site installation time. |
| 18 | Rugged construction withstands 24/7 continuous industrial operation. |
| 19 | Cooling water circuit can be closed-loop for water conservation. |
| 20 | Access platforms and ladders available for safe top-side maintenance. |
| 21 | Thrust roller controls axial movement and keeps drum on track. |
| 22 | Wear-resistant liners available for highly abrasive materials. |
| 23 | Smooth low-noise operation suitable for indoor plant installation. |
| 24 | Can be integrated with existing conveying and dust collection systems. |
| 25 | Multiple drums can be arranged in series for staged cooling. |
| 26 | Thermal insulation option reduces heat loss to surroundings. |
| 27 | Instrumentation ports available for temperature and pressure monitoring. |
| 28 | Competitive factory direct pricing with flexible delivery schedule. |
| 29 | Complete after-sales support including spares and technical service. |
| 30 | Available as cooler, dryer, or combined cooler-dryer in one unit. |
FAQ

| 1 | What is a rotary drum cooler used for? | It is used to continuously cool hot bulk materials such as fly ash, clinker, slag and chemical powders by rotating the material through a drum with air or water cooling. |
| 2 | How does a rotary drum cooler work? | The drum rotates slowly, internal flights lift and shower the material. Cooling air flows counter-current or water circulates in a jacket, transferring heat from the material. |
| 3 | What materials can it cool? | It can cool fly ash, cement clinker, slag, limestone, sand, mineral powder, chemical granules and other free-flowing bulk solids at high temperature. |
| 4 | What is the difference between direct and indirect cooling? | Direct cooling passes air through the drum contacting the material. Indirect cooling uses a water jacket around the shell with no product contact, for hygienic or dusty materials. |
| 5 | What size rotary drum do I need? | Size depends on your throughput (t/h), inlet temperature and desired outlet temperature. We calculate based on thermal load. Typical diameters are 0.8-2.5m with lengths 6-20m. |
| 6 | How is the drum driven? | Most heavy-duty units use a girth gear ring around the drum, meshing with a pinion on a gearmotor. Smaller units may use chain drive or friction rollers. |
| 7 | What supports the rotating drum? | The drum rides on two pairs of hardened steel support rollers that engage with machined riding rings welded to the drum shell. A thrust roller controls axial movement. |
| 8 | What is the typical discharge temperature? | With proper sizing and cooling media flow, typical discharge temperature is below 80°C from a 300°C inlet. Lower temperatures are achievable with longer drums or more cooling area. |
| 9 | Do you provide custom designs? | Yes, we customize drum diameter, length, speed, cooling method, materials, inlet/outlet configuration and instrumentation. Send us your process data for a tailored design. |
| 10 | How long is the delivery time? | Standard models ship in 45-60 days. Custom units with special materials or designs require 60-90 days including engineering, fabrication and testing. |
| 11 | What maintenance is required? | Periodically inspect support rollers and girth gear teeth, lubricate bearings per schedule, check end seals, and inspect internal liners. The flanged ends allow quick internal access. |
| 12 | Can I see a drawing before ordering? | Yes, we provide GA drawings with dimensions, foundation loads and inlet/outlet positions for your review and approval before fabrication begins. |
| 13 | What is the power consumption? | Power depends on drum size and material, typically 5.5kW to 75kW. Larger drums handling higher tonnage require proportionally more drive power. |
| 14 | Is the drum sealed against dust? | Yes, the inlet and outlet housings have flexible seals where they meet the rotating drum. The entire system is enclosed to prevent dust leakage during operation. |
| 15 | Can multiple drums be used in series? | Yes, for very high inlet temperatures or strict outlet requirements, multiple drums can be arranged in series with intermediate conveying to achieve staged cooling. |
| 16 | What water quality is needed for cooling? | For the water jacket, clean circulating water is recommended. Closed-loop cooling towers or chillers are commonly used. Water temperature and flow are sized based on heat load. |
| 17 | How is the drum aligned on site? | The factory pre-aligns components. On site, the support roller heights are adjusted so the drum rides level and thrusts against the thrust roller. We provide supervision if needed. |
| 18 | What wear parts need replacement? | Common wear parts: support roller tires, girth gear teeth, end seals, internal lifter flights, and wear liners. We supply original spares for proper fit and performance. |
| 19 | Can the drum handle abrasive materials? | Yes, we can install replaceable wear liners made of cast stone, ceramic or alloy steel for highly abrasive materials like clinker or slag. This extends drum life significantly. |
| 20 | What is the warranty? | We provide 12 months warranty after commissioning covering manufacturing defects. Wear parts are excluded from warranty but available as spares. |
| 21 | Can it be used as a dryer instead of a cooler? | Yes, the same rotary drum design can be configured as a dryer using hot air instead of cooling media, or as a combined dryer-cooler unit in one shell. |
| 22 | What foundation is required? | A reinforced concrete foundation designed for the loaded drum weight plus dynamic loads from rotation. We provide foundation load data and anchor bolt layout drawings. |
| 23 | Is variable speed available? | Yes, we offer VFD-controlled drive motors allowing adjustable rotation speed from 1 to 10 RPM, so you can optimize cooling for different materials and throughputs. |
| 24 | Can the drum be insulated? | Yes, we offer external insulation with aluminum cladding to reduce heat loss when using hot air for drying, or to protect operators from hot surfaces. |
| 25 | What is the noise level? | Properly aligned and lubricated girth gear drives operate at 75-85 dB(A), comparable to other industrial rotating equipment. Sound enclosures are available for noise-sensitive areas. |
| 26 | Do you handle installation? | We provide detailed installation drawings and can send a field service engineer to supervise erection and commissioning. Local crews handle the physical assembly under our guidance. |
| 27 | How do I get a quotation? | Please provide: material name, inlet/outlet temperature, required capacity t/h, available space, and power supply. We reply with a detailed quotation and preliminary layout within 3-5 working days. |
| 28 | Can the drum be elevated on a structure? | Yes, the skid base can be designed at any elevation with extended supports, or we can supply the drum separately for mounting on your existing steel structure. |
| 29 | What certifications do you provide? | We provide material test certificates, welding procedure specifications, and NDT reports (ultrasonic/radiographic) for the drum shell. Third-party inspection by SGS/BV/TUV is welcome. |
| 30 | How do you compare to other manufacturers? | We offer heavy-duty girth gear design, complete skid-mounted packages, custom engineering, competitive factory pricing and global project references. Contact us for a detailed comparison. |




